Granta MI connection#
Connection builder#
- class Connection(api_url, session_configuration=None)#
Connects to an instance of Granta MI.
This is a subclass of the
ansys.openapi.common.ApiClientFactory
class. All methods in this class are documented as returningApiClientFactory
class instances of theansys.grantami.bomanalytics.Connection
class instead.- Parameters:
- api_url
str
Base URL of the API server.
- session_configuration
SessionConfiguration
, optional Additional configuration settings for the requests session. The default is
None
, in which case theSessionConfiguration
class with default parameters is used.
- api_url
Notes
For advanced usage, including configuring session-specific properties and timeouts, see the ansys-openapi-common API reference. Specifically, see the documentation for the
ApiClientFactory
base class and theSessionConfiguration
class.To create the connection to Granta MI, you perform three steps:
Create the connection builder object and specify the server to connect to.
Specify the authentication method to use for the connection and provide credentials if required.
Connect to the server, which returns the connection object.
The examples show this process for different authentication methods.
Examples
>>> cxn = Connection("http://my_mi_server/mi_servicelayer").with_autologon().connect() >>> cxn <BomServicesClient: url=http://my_mi_server/mi_servicelayer>
>>> cxn = ( ... Connection("http://my_mi_server/mi_servicelayer") ... .with_credentials(username="my_username", password="my_password") ... .connect() ... ) >>> cxn <BomServicesClient: url=http://my_mi_server/mi_servicelayer>
- with_autologon()#
Set up client authentication for use with Kerberos (also known as integrated Windows authentication).
The default operation of this method is to attempt to connect to the API and to use the provided
WWW-Authenticate
header to determine if Negotiate authentication is supported by the server. If so, Negotiate will then be used for authentication.If Negotiate authentication is not supported by the server, an exception is raised.
- Returns:
ApiClientFactory
Current client factory object.
- Raises:
ConnectionError
If the server does not support Negotiate authentication.
Notes
Requires the user to have a valid Kerberos Ticket-Granting-Ticket (TGT).
On Windows, this is provided by default.
On Linux, this requires the
[linux-kerberos]
extension to be installed and your Kerberos installation to be configured correctly.
- with_credentials(username, password, domain=None, authentication_scheme=AuthenticationScheme.AUTO)#
Set up client authentication for use with provided credentials.
The default operation of this method is to attempt to connect to the API and to use the provided
WWW-Authenticate
header to determine whether NTLM or Basic Authentication should be used. The selected authentication scheme will then be configured for use.- Parameters:
- username
str
Username for the connection.
- password
str
Password for the connection.
- domain
str
, optional Domain to use for connection if required. The default is
None
.- authentication_scheme
AuthenticationScheme
The authentication scheme to use.
Tip
Added to
ApiClientFactory.with_credentials
in version 2.1 ofansys-openapi-common
.
- username
- Returns:
ApiClientFactory
Original client factory object.
- Raises:
ConnectionError
If the server does not support Basic or NTLM authentication (Windows clients only).
Notes
NTLM authentication is not currently supported on Linux.
- with_oidc(idp_session_configuration=None)#
Set up client authentication for use with OpenID Connect.
- Parameters:
- idp_session_configuration
SessionConfiguration
, optional Additional configuration settings for the requests session when connected to the OpenID identity provider.
- idp_session_configuration
- Returns:
OIDCSessionBuilder
Builder object to authenticate via OIDC.
Notes
OIDC Authentication requires the
[oidc]
extra to be installed.
- with_anonymous()#
Set up client authentication for anonymous use.
This does not configure any authentication or authorization headers. Users must provide any authentication information required themselves.
Clients relying on custom authentication such as client certificates or non-standard tokens should use this method.
- Returns:
ApiClientFactory
Original client factory object.
- connect()#
Finalize the BoM Analytics client and return it for use.
Authentication must be configured for this method to succeed.
- Returns:
BomAnalyticsClient
Client object that can be used to connect to Granta MI and perform BoM Analytics operations.
- Raises:
ValueError
When the client is not fully configured.
ConnectionError
If the resulting client cannot connect to the BoM Analytics service.
LicensingException
Error raised if no licenses were found.
BoM Analytics client#
- class BomAnalyticsClient(servicelayer_url, **kwargs)#
Communicates with Granta MI. This class is instantiated by the
Connection
class described earlier and should not be instantiated directly.- property maximum_spec_link_depth: int | None#
Maximum number of specification-to-specification links that are followed when processing a query. If a maximum is specified, specification-to-specification links are truncated at the specified depth, and only coatings and substances identified up to and including that point are included in the analysis.
The default is
None
, in which case no limit is applied to the number of specification-to-specification links. This might lead to performance issues if there are large numbers of specification-to-specification links present in the database.This parameter is supported with Restricted Substances Reports 2023 R2 and later. With older reports, this parameter has no effect, all specification-to-specification links are followed.
Added in version 1.2.
Note
This limit applies to each branch of the BoM individually. This is not a global limit on the number of specification-to-specification links that are traversed across the entire BoM. Instead it is a limit on the maximum depth of specifications below any individual specification node.
- Returns:
Optional
[int
]Maximum depth of specification-to-specification links that are followed.
- run(query: MaterialImpactedSubstancesQuery) MaterialImpactedSubstancesQueryResult #
- run(query: MaterialComplianceQuery) MaterialComplianceQueryResult
- run(query: PartImpactedSubstancesQuery) PartImpactedSubstancesQueryResult
- run(query: PartComplianceQuery) PartComplianceQueryResult
- run(query: SpecificationImpactedSubstancesQuery) SpecificationImpactedSubstancesQueryResult
- run(query: SpecificationComplianceQuery) SpecificationComplianceQueryResult
- run(query: SubstanceComplianceQuery) SubstanceComplianceQueryResult
- run(query: BomImpactedSubstancesQuery) BomImpactedSubstancesQueryResult
- run(query: BomComplianceQuery) BomComplianceQueryResult
- run(query: BomSustainabilityQuery) BomSustainabilityQueryResult
- run(query: BomSustainabilitySummaryQuery) BomSustainabilitySummaryQueryResult
Run a query against the Granta MI database.
- Parameters:
- query
A compliance, impacted substances, or sustainability query object.
- Returns:
Query
Result
Specific result object based on the provided query, which contains either the compliance, impacted substances, or sustainability results.
- Raises:
GrantaMIException
Error raised if the server encounters an error while processing the query with a severity of
critical
. This indicates that Granta MI is running and the BoM Analytics service is available, but the query could not be run, probably because of a missing database or table.ApiException
Error raised if the Granta MI server is not able to return a response, probably because of an internal configuration error or the BoM Analytics service not being installed.
- set_database_details(database_key='MI_Restricted_Substances', material_universe_table_name=None, in_house_materials_table_name=None, specifications_table_name=None, products_and_parts_table_name=None, substances_table_name=None, coatings_table_name=None, process_universe_table_name=None, location_table_name=None, transport_table_name=None)#
Configure the database key and table names if different from the defaults.
A database key is required if Granta MI is configured to use a value other than
MI_Restricted_Substances
. A table name is required for each table in the Restricted Substances database that has been renamed.- Parameters:
- database_key
str
, optional Database key for the Restricted Substances database. The default is
None
, in which caseMI_Restricted_Substances
is used.- material_universe_table_name
str
, optional Name of the table that implements the
MaterialUniverse
schema. The default isNone
, in which caseMaterialUniverse
is used.- in_house_materials_table_name
str
, optional Name of the table that implements the
Materials - in house
schema. The default isNone
, in which caseMaterials - in house
is used.- specifications_table_name
str
, optional Name of the table that implements the
Specifications
schema. The default isNone
, in which caseSpecifications
is used.- products_and_parts_table_name
str
, optional Name of the table that implements the
Products and parts
schema. The default isNone
, in which caseProducts and parts
is used.- substances_table_name
str
, optional Name of the table that implements the
Restricted Substances
schema. The default isNone
, in which caseRestricted Substances
is used.- coatings_table_name
str
, optional Name of the table that implements the
Coatings
schema. The default isNone
, in which caseCoatings
is used.- process_universe_table_name
str
, optional Name of the table that implements the
ProcessUniverse
schema. The default isNone
, in which caseProcessUniverse
is used.- location_table_name
str
, optional Name of the table that implements the
Location
schema. The default isNone
, in which caseLocation
is used.Added in version 2.0.
- transport_table_name
str
, optional Name of the table that implements the
Transport
schema. The default isNone
, in which caseTransport
is used.Added in version 2.0.
- database_key
Notes
The database key and table names are configurable, but they only need to be specified if they have been modified from the defaults. Here are the default key and table names:
Database key: MI_Restricted_Substances
Table names:
MaterialUniverse
Materials - in house
Specifications
Products and parts
Restricted Substances
Coatings
ProcessUniverse
Location
Transport
Examples
>>> cxn = Connection("http://my_mi_server/mi_servicelayer").with_autologon().connect() >>> cxn.set_database_details(database_key = "MY_RS_DB", ... in_house_materials_table_name = "My Materials")
Log messages#
- class LogMessage(severity, message)#
Message returned by Granta MI when running the query.
Messages marked with the error
severity
are more likely to produce incorrect results and should be treated with increased caution.
Exceptions#
- class GrantaMIException#
Provides the critical error message to show if processing a BoM Analytics query fails.
- class LicensingException#
Raised when an operation cannot be performed due to a lack of appropriate license.